AMBIRAD QUARTZ GLOW INSTANT INFRA-RED HEATERS INSTALLATION AND OPERATING MANUAL INDEX Section Introduction and Document Index Installation Requir
2. Use a minimum of 1.0mm2 H05RN-F supply cable with 2 poles and earth and sleeve with silicon glass fibre braided (250°C) sleeving. The live and n
1.5 Technical Details. Table 1 Model ref Voltage Lamps x Power Total Power Current per lamp Amps per phase V ph kW kW a a Apollo QH 15-1 Sing
2. Assembly Instructions. PLEASE READ this section prior to assembly to familiarise yourself with the components and tools you require at the
2.4.2 Titan Mobile heater The support stand for the Titan Static heater is supplied in two halves for ease of packing. 1. Interlock the two base p
Small Flat Head Screwdriver 3. Servicing Instructions. These appliances should be serviced annually by a competent person to ensure safe and efficien
4. Replacing Parts. 4.1 Replacing the lamp - general It is very important that your replacement lamp is exactly the same as the one it was supplied w
4.3 Sorrento Range: 1. Ensure the heater and lamp are cool and the power supply is disconnected by removing the plugs from the socket outlet - both p
11. The lamp should now be removed from the heater as shown below. 12. Refit the new lamp in reverse order ensuring that no wires get trapped
Introduction. height regulations are adhered to at the mounting heights specified. All Dimensions shown are in mm unless PLEASE READ thi
Technical Support: Tel: 01384 489 200 Fax: 01384 489 707 [email protected] www.ambiradgroup.co.uk Document reference number GB/QG/004/0414
1.1 Health and Safety AmbiRad heaters must be installed in accordance with the relevant codes and practices. Due account should a
AmbiRad Apollo Range AmbiRad Sorrento Range AmbiRad Titan Range Single Unit Two Units Joined Three Units Joined Wall Mounted Ceiling Hung Wall
1.3.1 Apollo range: • The heater must be mounted in such a way that the halogen lamp does not slant more than 4° from the horizontal, when viewed fr
1. When wall mounting, securely fasten the L-shaped wall brackets to the mounting surface using both of the fixing holes in the short part
• When hanging from a ceiling two chains of equal length and gauge are required and should be selected with fixings that are more than adequate to h
1. Fix the heater assembly to the chains via the hole in the centre of the joining bar as shown below and ensure the heater faces directly down when
1.4 Electrical Connections 1.4.1 General • Warning - this appliance must be connected to an earthed supply. • Pre-wired heaters are either fitted