AMBIRAD QUARTZ GLOW
INSTANT INFRA-RED HEATERS
INSTALLATION AND OPERATING MANUAL
INDEX Section
Introduction and Document Index
Installation Requirements ------------------------------------------------- 1
Assembly Instructions ----------------------------------------------------- 2
Commissioning Instructions ---------------------------------------------- 3
Servicing Instructions ------------------------------------------------------ 4
Spare Parts ------------------------------------------------------------------ 5
Fault Finding Guide -------------------------------------------------------- 6
Replacing Parts ------------------------------------------------------------- 7
User and Operating Instructions ---------------------------------------- 8
WARNINGS
AmbiRad equipment must be installed and maintained in accordance with the relevant
codes and practices. Due account should also be taken of any obligations arising from the
Health and Safety at Works Act 1974 or relevant codes of practice. In addition the
installation must be carried out in accordance with the current IEE wiring regulations (BS
7671), BS 6896 (Industrial & Commercial) and any other relevant British Standards and
Codes of Practice by a qualified installer. All external wiring MUST comply with the current
IEE wiring regulations.
Instruction Manual
Part No. 700505
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - AMBIRAD QUARTZ GLOW

AMBIRAD QUARTZ GLOW INSTANT INFRA-RED HEATERS INSTALLATION AND OPERATING MANUAL INDEX Section Introduction and Document Index Installation Requir

Page 2 - Document Index

2. Use a minimum of 1.0mm2 H05RN-F supply cable with 2 poles and earth and sleeve with silicon glass fibre braided (250°C) sleeving. The live and n

Page 3 - 1.2 Model Definitions

1.5 Technical Details. Table 1 Model ref Voltage Lamps x Power Total Power Current per lamp Amps per phase V ph kW kW a a Apollo QH 15-1 Sing

Page 4 - 1.3 Mounting the unit

2. Assembly Instructions. PLEASE READ this section prior to assembly to familiarise yourself with the components and tools you require at the

Page 5 - 1.3.2 Sorrento range:

2.4.2 Titan Mobile heater The support stand for the Titan Static heater is supplied in two halves for ease of packing. 1. Interlock the two base p

Page 6

Small Flat Head Screwdriver 3. Servicing Instructions. These appliances should be serviced annually by a competent person to ensure safe and efficien

Page 7

4. Replacing Parts. 4.1 Replacing the lamp - general It is very important that your replacement lamp is exactly the same as the one it was supplied w

Page 8

4.3 Sorrento Range: 1. Ensure the heater and lamp are cool and the power supply is disconnected by removing the plugs from the socket outlet - both p

Page 9

11. The lamp should now be removed from the heater as shown below. 12. Refit the new lamp in reverse order ensuring that no wires get trapped

Page 12 - 2. Assembly Instructions

Introduction. height regulations are adhered to at the mounting heights specified. All Dimensions shown are in mm unless PLEASE READ thi

Page 13 - 2.4 Titan range:

Technical Support: Tel: 01384 489 200 Fax: 01384 489 707 [email protected] www.ambiradgroup.co.uk Document reference number GB/QG/004/0414

Page 14 - 3. Servicing Instructions

1.1 Health and Safety AmbiRad heaters must be installed in accordance with the relevant codes and practices. Due account should a

Page 15 - 4. Replacing Parts

AmbiRad Apollo Range AmbiRad Sorrento Range AmbiRad Titan Range Single Unit Two Units Joined Three Units Joined Wall Mounted Ceiling Hung Wall

Page 16 - 4.3 Sorrento Range:

1.3.1 Apollo range: • The heater must be mounted in such a way that the halogen lamp does not slant more than 4° from the horizontal, when viewed fr

Page 17 - 4.4 Titan range:

1. When wall mounting, securely fasten the L-shaped wall brackets to the mounting surface using both of the fixing holes in the short part

Page 18

• When hanging from a ceiling two chains of equal length and gauge are required and should be selected with fixings that are more than adequate to h

Page 19

1. Fix the heater assembly to the chains via the hole in the centre of the joining bar as shown below and ensure the heater faces directly down when

Page 20 - Replaces GB/QG/004/0813

1.4 Electrical Connections 1.4.1 General • Warning - this appliance must be connected to an earthed supply. • Pre-wired heaters are either fitted