2. Use a minimum of 1.0mm2 H05RN-F supply
cable with 2 poles and earth and sleeve with
silicon glass fibre braided (250°C) sleeving.
The live and neutral wires must be
connected to the terminal block. See below.
3. The green/yellow wire should be connected
to the clamp marked with the earth symbol
using a suitable wire terminal. Fit cord grip
and terminal box saddle once wired.
4. Tighten the barrel nut of the compression
gland so that the rubber seal grips the
cable.
5. To prevent water
ingress, ensure that
the cover is secured
well by hand
tightening all for
screws evenly.
1.4.4 Titan range:
Warning – this appliance must be earthed.
The Titan series heaters are fitted with 3.0
metres of supply cable and a moulded 13A
plug therefore it is unnecessary to remove
the terminal cover plate in order to carry out
normal installation of this model.